Siemens 6RA7087-6FV62-0-Z SIMOREG DC Converter

New 
On request
Refurbished   
On request
Want to exchange a faulty product?
Receive a discount on your purchase when you turn in a faulty product. Upon receipt, we will check the product to determine its eligibility according to the terms and conditions.
Repair  
Available
We can repair this product for you.
 

Product Information

Product Family: SIMOREG DC MASTER 6RA70

The Siemens 6RA7087-6FV62-0-Z is a SIMOREG DC-MASTER DC converter and industrial DC motor controller from the SIMOREG DC MASTER 6RA70 family. It provides 850 A DC armature current control from a 460 V AC, 3-phase supply and supports 4-quadrant operation with regenerative control. The configured Z package contains G94, D64, S00, K01, and K11 options, making this unit an exact replacement reference for installed Siemens SIMOREG drive systems.

The converter uses an RS-485 / RS-232 serial interface through a SUB-D connector and supports the USS protocol as well as peer-to-peer drive communication. The K11 option provides the Local Bus Adapter, while K01 provides the ADB adapter for Slots D and E. A replacement requires the correct electrical rating, option configuration, firmware compatibility, and transfer of the existing parameters using the OP1S Operator Panel or Siemens DriveMonitor / SIMOVIS software. Parameters can be stored in internal non-volatile EEPROM/FLASH memory for backup and restore.

The integrated PMU 7-segment display shows operating status codes, parameter numbers, actual values, warnings, and fault codes such as Fxxx and Axxx. Fault analysis can also use the OP1S Operator Panel, DriveMonitor / SIMOVIS, the fault memory buffer r047, the warning memory buffer r049, and diagnostic r-parameters. For an internal electronics power supply fault that persists after checking the 24 V supply, repair or a tested exchange unit may be the faster route to restoring the existing DC drive.

Technical Specifications

ManufacturerSiemens
Part number6RA7087-6FV62-0-Z (Z=G94+D64+S00+K01+K11)
Model/typeSIMOREG DC-MASTER DC-Converter
Component typeDC motor controller
Product familySIMOREG DC MASTER 6RA70
Rated armature current850 A DC
Supply voltage460 V AC, 3-phase
Operating mode4-quadrant operation with regenerative control
Serial communication interfaceRS-485 / RS-232 via SUB-D connector
Serial communication protocolUSS
Drive-to-drive communicationPeer-to-peer bus
Local Bus AdapterLBA included through option K11
Adapter moduleADB adapter for Slots D and E included through option K01
Technology optionS00 included in configured Z option package
Parameter storageInternal non-volatile EEPROM/FLASH with parameter backup and restore
Commissioning and diagnostic softwareDriveMonitor / SIMOVIS
Product lifecycle statusDiscontinued; superseded by the Siemens SINAMICS DCM 6RA80 series

Programming and Configuration

Commissioning and parameterization are supported through the integrated PMU display, the OP1S Operator Panel, or Siemens DriveMonitor / SIMOVIS PC software. The internal non-volatile EEPROM/FLASH provides parameter storage, allowing parameters to be backed up and restored during replacement work.

Before commissioning a spare, transfer the existing parameter set through OP1S or a PC-based DriveMonitor setup and confirm firmware and option compatibility. The configured replacement must match the required G94, D64, S00, K01, and K11 options, including the K01 ADB adapter for Slots D and E and the K11 Local Bus Adapter.

Communication and System Integration

The SIMOREG converter provides an RS-485 / RS-232 serial communication interface through a SUB-D connector. The USS protocol supports parameter access and drive control within the installed drive system.

Peer-to-peer bus communication supports drive-to-drive linking. The K11 option supplies the Local Bus Adapter, while the K01 option includes the ADB adapter for Slots D and E. These option modules must match the configuration of the SIMOREG electronics box and installed system.

Diagnostics and Status Indication

The PMU 7-segment display provides operating status codes, parameter numbers, actual values, warnings, and fault codes in formats such as Fxxx and Axxx. Additional diagnostic access is available through the OP1S Operator Panel and Siemens DriveMonitor / SIMOVIS software.

For troubleshooting, use the fault memory buffer r047, warning memory buffer r049, and diagnostic r-parameters together with checks of the relevant supply, field, armature, and communication circuits indicated by the displayed fault code.

Status LED Indicators

LEDColor/StatusMeaning
PMU 7-segment displayDisplays operating status codes, parameter numbers, actual values, and fault or warning codes such as Fxxx and Axxx

Replacement and Spare Part Considerations

Use the complete part number 6RA7087-6FV62-0-Z and the Z option package G94+D64+S00+K01+K11 when checking a replacement. Confirm the 850 A DC armature rating, 460 V AC 3-phase supply, 4-quadrant regenerative operating mode, K01 ADB adapter, K11 Local Bus Adapter, and S00 technology option against the installed SIMOREG DC MASTER 6RA70 system.

A spare is not necessarily ready for immediate operation after installation. Transfer the parameter set using OP1S or DriveMonitor / SIMOVIS, then confirm firmware, communication settings, adapter modules, and the existing system configuration. The SIMOREG 6RA70 family is discontinued and has been superseded by the Siemens SINAMICS DCM 6RA80 series, so maintaining the installed legacy system requires careful like-for-like compatibility checks.

Error Codes & Fault Codes

The following error codes may be displayed during operation or diagnostics:

CodeNameDescriptionPossible CauseRecommended Action
F001Failure of main power supplyFailure of armature supply line voltage during operation.Line voltage interrupted, main contactor dropped out, line fuse blown, or supply voltage out of tolerance.Check line supply voltage, main fuses, contactor control, and power connection terminals.
F004Phase failure in line supplyPhase failure or asymmetric line voltage detected in the main armature supply.Line fuse blown, supply phase missing, or thyristor firing pulse failure.Check main incoming AC phases and fuses; check the line reactor and power connections.
F005Fault in field circuitExcitation field current does not reach its setpoint or the field supply voltage has failed.Open circuit in the motor field winding, blown field fuse, incorrect field parameters, or field module fault.Check field connections, field resistance, field current settings, and the field power supply.
F006Armature overcurrentArmature current exceeded the maximum threshold limit.Short circuit at the converter output, severe motor overload, dynamic load burst, or improper controller tuning.Inspect motor and power wiring for short circuit or earth fault; verify motor parameterization and current limits.
F040Electronics power supply faultInternal electronic supply voltages are outside permissible limits.Defective internal power supply board, control board fault, or external overload on 24 V supply outputs.Check the 24 V power supply and internal electronics board. If the fault persists, repair or replace the unit.

Frequently Asked Questions

What is the Siemens 6RA7087-6FV62-0-Z?

It is a SIMOREG DC-MASTER DC converter and DC motor controller from the SIMOREG DC MASTER 6RA70 family, rated for 850 A DC armature current and a 460 V AC, 3-phase supply.

Which options are included in this SIMOREG replacement?

The configured Z package contains G94, D64, S00, K01, and K11. K01 includes the ADB adapter for Slots D and E, and K11 provides the Local Bus Adapter.

How are parameters transferred to a replacement unit?

Parameters can be backed up and restored through the OP1S Operator Panel or Siemens DriveMonitor / SIMOVIS software, using the converter's internal non-volatile EEPROM/FLASH parameter storage.

Which communication interfaces and protocols are supported?

The converter supports RS-485 / RS-232 serial communication through a SUB-D connector, the USS protocol, and peer-to-peer drive-to-drive communication.

Where are SIMOREG fault codes displayed?

Fault and warning codes are shown on the PMU 7-segment display in formats such as Fxxx and Axxx. Further analysis is available through OP1S, DriveMonitor / SIMOVIS, fault memory buffer r047, warning memory buffer r049, and diagnostic r-parameters.

What should be checked for fault F006?

F006 indicates armature overcurrent. Inspect the motor and power wiring for a short circuit or earth fault, and verify motor parameterization and current limits.

Take advantage of our exchange formula

A defective product does not have to be worthless. At ABC Industrial Parts, you can hand in defective products and immediately benefit from a discount on your new purchase. This is a smart way to save money while contributing to a circular economy.

Play it safe with our warranty conditions

Industrial plants prefer to keep running invariably, no matter what. Therefore, it is essential that you can rely on high-quality products and/or sustainable repairs. With our warranty conditions, you can count on certainty, whether you choose new, used or repaired products.​​​​​​​

Data backup and recovery

Have you lost valuable parameters or data due to a malfunction while the manufacturer no longer provides support? At ABC Industrial Parts, we help you secure this data, both for common and specific products.

Specific firmware and hardware versions

If you are working with specific hardware or firmware versions that are no longer available from the manufacturer, ABC Industrial Parts is your partner. When making your enquiry, clearly state which versions you need, we will then look at the possibilities of supplying those versions, so that your installations continue to function optimally.